top of page
Search
pavelacovy

DIN rail LAN and LTE solution for remote energy monitoring and control applications with M-Bus Master.

Perseus Energy 285




Perseus Energy 285 is a DIN rail LAN and LTE solution for remote energy monitoring and control applications with M-Bus Master.


Perseus Energy 285 is a DIN rail mount device for environmental monitoring of a site of any size and complexity. Up to 100 external meters (and sensors) with 1000 values (variables) can be connected. Within one DIN rail unit there are 6 1W-UNI (RJ11) ports, 4 DI (Digital Inputs) with S0 pulse counters, RS-485 (Modbus/RTU), one WLD (Water Leak Detection) zone input, an M-Bus Master input, and 2 DO (Relay Outputs). Perseus Energy 285 can only be powered from 230V.




The combination of the RS-485 physical interface on the Perseus Energy 285, M-Bus Master and Modbus-RTU Meters API allows data to be read from third party electricity/gas/water meters, UPS or air conditioning products.

Perseus Energy 285 has a WLD zone input and 2 relay outputs that can be controlled via the device’s interface or according to the value of a connected sensor or detector, for example to control air conditioning, ventilation, automatic doors, etc.

The Perseus Energy 285 unit has a built-in LTE modem that serves as an SMS gateway for Perseus itself as well as other connected HW group devices, and also provides back up connectivity to the Portal.

Features: 

  • Ethernet: RJ45 (100BASE-T); WEB: Built-in web server

  • LTE: Global

  • 6xRJ11 port - max. 2 external sensors 1-Wire UNI per port

  • RJ11 sensors: Temperature, Relative Humidity (Indoor / Outdoor), Voltage, Current (0-30A or 4-20mA) and much more

  • RS-485 (Modbus/RTU): 1x terminal block

  • M-Bus Master: 1x terminal block

  • WLD: 1 zone for external Water Leak Detection sensing cable

  • DO (Digital Outputs): 2x DO (relays)

  • DI (Digital Inputs): 4x DI (dry contact)

  • Detectors: Smoke, door contact, fan failure detector, power presence, etc

  • Device Alerts: SNMP trap, email, SMS / Calls

  • Portal Alerts: Email, SMS / Calls, Device Invalid Alert

  • Open API: SNMP, XML, Modbus/TCP, MQTT

  • Professional product: IPv6, SNMP Traps, SNMP v3

  • Security: Radius - IEEE 802.1X, Admin and user accounts, HTTPs (customer certificate)

  • Meters API (LAN): HWg devices XML, Modbus/TCP, SNMP, MQTT

  • Data processing: Condition & Actions, Virtual sensors, Scheduler

Sensors





For more information please contact us over sales@ac-hw.com or call +420723069787